Induction Motor Slot Pole Combinations

Posted on by admin

The impact of the rotor slot number selection on the induction motors is investigated. Firstly, analytical equations will reveal the spatial harmonic index of the air gap magnetic flux density, connected to the geometrical features and the saturation of the induction motor. Then, six motors with different rotor slot numbers are simulated and studied with FEM. The stator is identical in all. Determination Of Rotor Slot Number Of An Induction Motor. 229 2 Information Content of the Search Coil Voltage It is well known that, for a P pole pair, induction motor with Z number of rotor slots, rotating at a mechanical frequency fr; the harmonic frequency of the flux observed on the stator reference frame is frsh and is given by (1) 1. During grid motor starting from zero rpm, this starting current flow is in the upper part of the bar close to the rotor OD. (due to the skin effect of current penetration). AS the motor increases speed the bar current is distributed down in the lower part of the bar & the frequency seen by the bar decreases (decreasing slip).

There are many much more interesting questions related to the pole number of induction motors, e.g.:
1. Does the induction motor supplied by the main grid (say, 50 Hz) increases its torque capability in 'p' times with growing pole number 'p' since its speed decreases in 'p' time (like in a gearbox)?
2. Let's we have an induction motor with p=2 and feed it from 50 Hz grid. Then we re-connect the winding coils to arrange p=4 and feed if grow 100 Hz grid. Are performances of these two motors different or the same? Please note excluding frequency and inter-coil connections all remained the same.
It depends on the required speed. n (rpm) = (60 x f) / N where:- f = frequency and N = number of pole pairs. The 60 is there to convert from revolutions per second to revolutions per minute as the frequency is in cycles per second. Pole pairs is there because that any pole must be constructed in a pairs top and bottom / left right, so with one cycle it will move half the distance.
If you are using 50Hz and have a two pole motor 60 x 50 / 1 = 3000 rpm. The induction motor will run at a slight less speed due to 'slip' which is what gives the motor its torque. For example 5.5kW, 400v, 2 pole motor will run at approximately 2880 rpm.
For a four pole machine, 60 x 50 / 2 = 1500 rpm so the same size motor at 5.5kW, 400v but 4 poles will have a nominal speed of 1500rpm but will run near 1455 rpm.
When selecting a three phase motor, the number of poles is chosen to achieve the speed of rotation that you require. Here are two tables, one for a 50 Hz power supply and one for a 60 Hz power supply:
The formula is n = 60 x f /p where n = synchronous speed; f = supply frequency & p = pairs of poles per phase. The actual running speed is the synchronous speed minus the slip speed.
For a 50 Hz three phase supply:

  1. For this example, refer to the motor equivalent circuit and calculations described above. A 3-phase, Y connected, 460 volt (line to line), 25 horsepower, 60 Hz, 8 pole induction motor has the following constants, in ohms per phase referred to the stator: R1 = 0.342 X1 = 0.561 Z1 = 0.342 + j0.561 R2 = 0.164 X2 = 0.265.
  2. The comparison of electromechanical characteristics of a 4-pole and a 6-pole induction motor with 36 stator slots in combination with 28, 33, 34, 44 and 46 rotor slots is presented.

2 poles or 1 pair of poles = 3,000 RPM (minus the slip speed = about 2,750 RPM or 6 -7% n)
4 poles or 2 pairs of poles = 1,500 RPM
6 poles or 3 pairs of poles = 1,000 RPM
8 poles or 4 pairs of poles = 750 RPM
10 poles or 5 pairs of poles = 600 RPM
12 poles or 6 pairs of poles = 500 RPM
16 poles or 8 pairs of poles = 375 RPM

For a 60 Hz three phase supply:

2 poles or 1 pair of poles = 3,600 RPM (minus the slip speed = about 2,750 RPM or 6 -7% n)
4 poles or 2 pairs of poles = 1,800 RPM
6 poles or 3 pairs of poles = 1,200 RPM
8 poles or 4 pairs of poles = 900 RPM
10 poles or 5 pairs of poles = 720 RPM
12 poles or 6 pairs of poles = 600 RPM
16 poles or 8 pairs of poles = 450 RPM

Pole

To determine the number of poles, you can read the data plate directly or calculate it from the RPM stated on the data plate or you can count the coils and divide by 3 (poles per phase) or by 6 (pairs of poles per phase). Where the power of the induction motor is constant, the torque increases at the rate that the speed decreases.
With the advent of variable frequency drive (VFD), you can have any frequency / rated volts you desire. I often see name plates with things like 575VAC, 42.5 Hz etc. When these 'specials' are made I usually see 6 pole machines - but that may be just a manufacturer's preference.

Induction Motor Slot Pole Combinations Diagram

36 pole induction motor

36 pole induction motor

Induction Motor Slot Pole Combinations List

Hi There,
I'm in the process of trying to design a 36 pole induction motor for one of our test beds in the factory. It'll be used to test a range of winches that we manufacture and by controlling this motor through a VSD we can perform certain tests without the primary gear box that gets fitted to the completed unit.
I've looked on the web at the various motor manufacturers - a motor of this size (55kW)does not exist as far as I can see, hence my efforts to design a fit for purpose motor.
Despite my best efforts, all I can achieve is a 25kW design, that runs, but with a terrible power factor (copper losses and a huge differential reaction are killing the machine).
My question (eventually) is this: is this a viable proposition in motor design? Should I be looking at a different type of motor (such as a brushless DC or similar)?
Has anybody had any experience with a motor of this size?
Best Regards